Please enter your values

Ambient temperature

Water supply temperature

Required hot water flow rate

L/day

unimo operating hours

h/day

Annual operating days

days/year

Calorific value Fuel

MJ/kg

CO2 emission factor Fuel

kg.CO2/kg

Fuel unit price

$/kg

Boiler efficiency

%

Electricity price

¢/kWh

CO2 emission factor Elec.

kg.CO2/kWh

Ambient temperature

Please input ambient temperature where the unimo will be installed.

[Note] Acceptable ambient temperature of unimo is from -10degC to 43degC.

Hot water supply temperature

The temperature of the hot water coming out of unimo. Select a temperature close to the required temperature or the supply temperature of the existing boiler.

Select 65℃ or 90 ℃.

Water supply temperature

The temperature of the water supplying to unimo for the production of hot water. Please enter the average temperature of the water supply such as city water.

[Note] The temperature range of water supply are -5℃ to 30℃ when hot water supply temperature is 65℃ and -5℃ to 65℃ when hot water supply temperature is 90℃.

Required hot water volume per day

Enter the total amount of hot water used per day.

The number of units is calculated from the entered the required water flow rate and the conditions.

unimo operating hours

Enter the expected unimo operating time in a day. Decide in consideration of peak cuts in power consumption and off-peak tariffs.

Fuel type

Select existing or comparative boiler fuel. Select existing or comparative boiler fuel from NG, LPG or heavy oil.

Calorific value Fuel

Enter the calorific value (heating value) as per fuel type.

The calorific value (heating value) is a direct indication of the energy available for the production of steam or hot water

[Note] Default value is automatically inputed. You can change this value as per actural.

CO2 emission factor Fuel

CO2 emission factor Fuel is the sum of emissions of CO2 of the boiler combustion for generating hot water or steam.

[Note] Default value is automatically inputed. You can change this value as per actural.

Fuel unit price

Enter the unit price of the fuel selected for the boiler.

Boiler efficiency

Enter the boiler efficiency of the existing or comparative boiler.
60% is entered in advance as a reference value.

Electricity price

Enter the unit price per kWh of electricity to be used.

Annual operating days

Enter the number of operating working days of unimo in a year.

CO2 emission factor Electricity

CO2 emission factor Electricity is the sum of emissions of CO2 of electricity generation process.
You can check this value by checking with Goverment or Electricity company web page.

[Note] Default value is automatically inputed. You can change this value as per actural.

Chilled water inlet temperature

A cooling heat source is required to operate unimoWW, when “Hot water + Chilled water” selected.
Enter the inlet water temperature of heat source.

[Note]The temperature range of heat source is -3℃ to 37℃.

Chilled water outlet temperature

Enter the outlet water temperature of unimo as heat source.

[Note]The minimum outlet temperature is -5℃. The recommended temperature differential between in and out is 5℃.