CO2 Heat Pump Hot Air Supply "EcoSirocco"
Introduction effect simulation

Easily estimate cost benefits and CO2 emission reductions to
consider new installation,or
replacement of existing equipment.

CO2 Heat Pump Hot Air supply

EcoSirocco

border_line
border_line

COPh5.5※ Heating air with heat pump efficiently.
Hot air temperature is up to 120degC. Higher temperature can supply by combined system with other package.

main_picture

About this simulation

  • 1.The simulation is a guide for introduction.
       When designing the system with EcoSirocco, consider the balance with other equipment.
  • 2.If you need a quote, please contact us.
  • 3.Mayekawa collects your information to understand your needs and provide you with better services. Please read our Privacy policy before using this simulation

Step1

Please enter necessary conditions

Required air flow

m3/h

Required air outlet temperature

Air inlet temparature

Air inlet relative humidity

%

Chilled water inlet temperature

Chilled water outlet temparature

Result

Required air flow

Enter the necessary flow rate per hour. (unit: m3/h)

The number of units is calculated from the entered the required air flow rate and the conditions.

[Note] Minimum flow rate is 1500m3/h

Required air outlet temperature

The temperature of the hot air coming out of EcoSirocco. Select a temperature close to the required temperature or the supply temperature of the existing boiler.

・The hot air supply temperature range are 60℃ to 120℃.
・If hot air above 120 ° C is required, the hot air must be heated by additional boiler.

Air inlet temparature

The temperature of the air suppling to EcoSirocco.

The air supply temperature range are -10℃ to 43℃.

Air inlet relative humidity

The relative humidity of air supplying to EcoSirocco. (unit: %)

The range of 0% to 100% can be entered.

Chilled water inlet temperature

The water temperature of heat source supplying to EcoSirocco.

EcoSirocco is a system that takes heat from water and generates hot air. Therefore, a cold heat source is required.

The heat source can be the waste heat from the process or can be supplied with cold water for cooling.

The temperature range are 0℃ to 40℃

Chilled water outlet temparature

The water temperature of heat source coming out of EcoSirocco.

EcoSirocco is a system that takes heat from water and generates hot air. Therefore, a cold heat source is required.

The heat source can be the waste heat from the process or can be supplied with cold water for cooling.

The minimum outlet temperature is -5℃. The recommended temperature differential between in and out is 5℃.